Radio Shuttle Racking System for Freezed Warehouse

Product Details
Customization: Available
Usage: Industrial, Warehouse Rack
Material: Steel
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001
  • Radio Shuttle Racking System for Freezed Warehouse
  • Radio Shuttle Racking System for Freezed Warehouse
  • Radio Shuttle Racking System for Freezed Warehouse
  • Radio Shuttle Racking System for Freezed Warehouse
  • Radio Shuttle Racking System for Freezed Warehouse
  • Radio Shuttle Racking System for Freezed Warehouse
Find Similar Products

Basic Info.

Model NO.
WAP 2.0
Structure
Remote Controll
Type
Compact Storage
Mobility
Mobile
Height
180mm
Weight
500kg-1500kg
Closed
Closed
Development
New Type
Serviceability
for Special Purpose
Speed
0.6-0.8m/S
Guide Rail Thickness
2.5,2.75,3.0mm
Battery
Lithium Battery
Height of Cart
183mm
Transport Package
Packed in Wooden Case with Pallets
Specification
1200*1000 STANDARD
Trademark
WAP
Origin
Shanghai
HS Code
84798992
Production Capacity
1000 Units Per Year

Product Description

1. Product Specifications:
 
Radio Shuttle Racking System for Freezed Warehouse, is a deep lane storage and retrieval system. The pallet shuttle system consists in a specific rack and a mobile shuttle. This shuttle is a self-powered device that runs on rails in the storage lanes for the loading and unloading of pallets. It is transported to its location at the front or the back of a lane (in case of open back side) by a standard forklift. Once at its home position, the shuttle performs the loading and unloading tasks without any human intervention.
These tasks are instructed by the fork lift driver using a remote control. Once the tasks are completed the shuttle returns to its home position and is then ready to be transported to a new location for a new task.
Radio Shuttle Racking System for Freezed Warehouse
 
By introducing more shuttles into a racking system, the performance will increase. The system can be used for new installations as well as for refurbishments, and is independent from the number and the depth of the lanes. The systems is widely used in food, FMCG, Cold chain logistic area, etc.


2. Clear benefits and advantages: 
A shuttle system offers highest possible density storage and is considered the best solution amongst not fully automated systems
The system is semi-automated and works in combination with a fork lift truck.
While the shuttle transports the load within the racking, the fork lift driver is free to work elsewhere, thus he is optimizing his working time.
Compact storage of another article (SKU) on every lane.
Ability to handle the pallets FIFO and LIFO. And the possibility to change at every time. Both can be available in the same block. What we call 'Maximum Flexibility' 
Radio Shuttle Racking System for Freezed Warehouse

2. Techincal Specifications: 
Parameters Standard Specifications
Loading capcity max. Max 1500kg
MOVE Running speed Vmax_empty:1.0m/s
Vmax_full:0.8m/s
Drive motor Brushless servo motor
48VDC  600W
Servo driver Customized servo driver
LIFT Lift motor 48V DC  500W
Lift height ≤45mm
Control system Siemens S7-1200 PLC
Remoter:two-way Customized IMT
Power supply Lithium battery
Battery capacity 48V,30AH
Running time ≥8h
Charging time 3~4H
 Battery lifetime Charge times≤1000
Operation mode  Remote control
Running noise ≤60db
Painting color frame(black)
Working Temperature Normal: 0ºC~50ºC,  Cold type: -25ºC
Humidity:  5% ~ 95%

Radio Shuttle Racking System for Freezed Warehouse

3. Shuttle operational requirements
Pallet
For a good operation and the shuttle is a moving transport device, a  good quality pallet is required. The pallet surface should be closed (no mesh patterns), unless stated otherwise. 
Wooden pallets of good quality, allowing the span between the 2 pallet-rails, with a maximum pallet deflection of 20mm
The pallet and/or load have a fully closed strip in the middle for the detection of the sensors 
Not acceptable or to be tested for approval:
Damaged pallets
Pallets with too high deflection
Pallets with an open bottom construction
Containers and metal support structures 
Ambient conditions
Operating temperature: from -30°C to +35°C
Relative humidity: max 80%
Shuttle better always remains in the  cold-store environment
Before switching on the power again the shuttle must be dry (no condensation)        
Not acceptable:               
·         Dusty, sandy, humid, combustible,… environments
Radio Shuttle Racking System for Freezed Warehouse

4. Warehouse conditions/Cold Store 
Keep the shuttle always INSIDE the Cold Store
But charge the batteries always OUTSIDE the Cold Store
    charge only after warming up to normal temperature
So in 3 shift applications best to use 3 battery packs :
              1 working in the shuttle
              1 warming up
              1 charging in the battery station.
Battery and shuttle must be completely dry before connecting
For existing Cold Store Rooms check for condensation or icing on rails, floors
For NEW Cold Store Warehouses check if a intermediate area is foreseen between ambient and frozen zone, humidity around a frozen storage zone is prohibited.

5. RFQ Documents:
Before you send us your requirement for quotation, please prepare the following information:
Warehouse layout CAD drawings if available.
Pallet size, entry side, width, depth, height of goods.
Loading weight per pallet.
Clear height of the warehouse
Your forklift information, working aisles width and max. reaching height.
Your intra logistic flow within the warehouse.
CERTIFICATES
 Radio Shuttle Racking System for Freezed Warehouse

FACTORY
 
Radio Shuttle Racking System for Freezed Warehouse

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier